Five releases from the late summer of 2026 sit behind this piece, and for once none of them is out of window. Four are operators or their vendors buying measurement in hardware and in commitments. One is a method paper. The asymmetry between those two groups is the article.
On 24 August 2026, dateline Stavanger, Emerson announced that Equinor had selected its advanced measurement instrumentation under a 13-year frame agreement including options, covering measurement instrumentation, analytical technologies and lifecycle services across Equinor's global offshore and onshore operations [3]. That is a partner release. It is a vendor speaking about an operator: Equinor is named and is not quoted, and Equinor's own newsroom contains zero occurrences of the word "Emerson". The release body contains no mention of AI, artificial intelligence, machine learning, agentic systems, language models, analytics or data. The word "digital" appears twice, in wording attributed jointly to both companies. The technology list on that page, from subsea multiphase flow meters to safety, pressure and temperature instrumentation, is a 40-year history of what Equinor has used from Emerson, not the scope of the new agreement, and it should not be read as scope.
On the same day, dateline Houston, SLB launched the ExaCT electrical downhole coiled tubing control system on its own newsroom, replacing pressure-dependent hydraulic actuation with electrical communication, power delivery and telemetry, plus downhole measurements for real-time actuation and verification of intervention tools [4]. No operator is named in the release body. The performance figures on that page are vendor-reported single-well trial figures with the operator unnamed, and they are quotable precisely because nobody has to stand behind them: in 1 well intervention with 6 laterals, intervention time reduced by approximately 175 hours, each lateral entered in about 12 minutes against 6 to 8 hours with conventional hydraulic systems, more than 21,000 feet of reservoir contact stimulated, and fluid consumption cut by more than 3,000 barrels. There is no AI in that release either. Every occurrence of "Artificial Intelligence", "agentic" and "Autonomous" on the fetched page is in the slb.com site navigation menu, not in the release. The automation content is one clause about a foundation for increasingly automated intervention workflows.
Two weeks earlier, on 10 August 2026, Baker Hughes announced an award from Searah North Ganal Limited, a subsidiary of Searah Limited, the Eni and PETRONAS joint venture, to supply subsea production systems and digital solutions for the Kutei Northern Hub development offshore Indonesia, covering the Geng North and Gehem fields [5]. Again a vendor speaking about an operator: this is Baker Hughes' own release and the operator has not spoken here. The scale is 17 deepwater horizontal tree systems with associated manifolds, connections, control and distribution systems. The digital component carries no number, and the one digital sentence describes Cordant asset protection and condition monitoring, which is digital condition monitoring and not AI. The words artificial intelligence, AI, machine learning and analytics do not appear on the page.
And on 31 August 2026, signing dateline Riyadh, page published 3 September, Quantinuum announced a non-binding memorandum of understanding with Aramco to explore a series of industrial use cases, enhance quantum computing capabilities and prepare for a potential research collaboration focused on fault-tolerant quantum computing [6]. This is the vendor's own account and not Aramco's, whose newsroom carries no Quantinuum item at all. It is an intent-to-explore instrument: no hardware, no deployment, no dollar figure, no timeline. Nothing has been built and nothing has been run. We have no quantum delivery experience of our own and this leg is read from the source and from nothing else.
That is four operator legs carrying the occasion, and not one of them says anything about AI. The AI question in this piece is ours. No operator here claimed a recovered number, and a reader looking for one will not find it.
The one machine learning item, and whose it is
The fifth item is SPE Journal 234678, published open access on 9 September 2026: a Swin-transformer GAN, SwinIRGAN, that upscales micro-CT rock imagery from 10.72 to 2.68 micrometres per pixel, a factor of 4 [1]. The authors are academic, at the Eastern Institute of Technology, Imperial College London and the University of New South Wales, and no operator is named anywhere in it. It is a method paper, not a deployment and not a statement of intent by anyone who drills. It cannot anchor a piece and it does not anchor this one; it is here for the parallel it draws with work of our own.
Its reported figures are 99.48% accuracy on Euler number for the biogenic carbonate dataset, 97.05% on higher-resolution extrapolation, and a 15.59% improvement in Euler number over the baseline on MRCCM. Every one of those is taken from the JPT summary and not from the paper, because the OnePetro article landing page at the DOI returns 403 [2]. They are reported by academic authors who name no operator, and that qualification travels with each of them everywhere below.
We should also grant, at the outset, the pairing our own published validation framework already makes: the same VeerNet checkpoints that score a peak mask IoU of only 0.51 reach a peak coefficient of determination of 0.9891, a lowest mean absolute error of 0.0132 and a lowest mean squared error of 0.0004 against ground truth at 300 interpolated depth points [7]. Choosing the wrong acceptance quantity understated a good model by a mile. That is not the finding here. The finding here is a distinction the framework never had to draw, because our digitiser never claimed it: whether recovered detail was read back out of a measurement, or supplied by a prior.
Four ways to get a number below your floor
Read the five together and there are, on our reading, four ways to produce a number that sits below your measurement floor. This is our framing of what this particular pool shows, not a taxonomy anyone else has published, and the boundaries between the middle two are where the money is.
You can buy a better instrument. That is what Equinor signed 13 years of, what SLB's electrical downhole telemetry sells, and what 17 subsea trees and condition monitoring put on the seabed. You can read back detail the instrument already recorded but your reduction threw away. You can have a model supply detail the instrument never recorded. Or you can wait for a machine that does not exist yet, which is what a non-binding quantum MOU is: the fourth route is in this argument as a category, not as anything we have done.
Only the middle two are ever confused with each other, and the confusion is expensive, because they fail in opposite directions on different quantities.
Reading back is real, and it is cheap
Reading back is not a euphemism. A segmentation head does not emit a line; it emits a probability band several pixels wide at every depth row, and that band, by being smoothly peaked, encodes the fractional position of the true centreline in the relative heights of its samples. Taking the integer per-column argmax throws that away by keeping only which sample is largest. Fitting a parabola through the argmax sample and its two immediate neighbours and reading the vertex reads it back, at a fractional position between the grid lines [7].
Nothing is invented in that operation. The information was in the measurement and the reduction was discarding it. On the deliverable it is the difference between a curve pinned to the integer lattice and one that clears R-squared 0.9891 with MAE 0.0132. Two bounds from our own file travel with those figures wherever they go: the parabolic estimator is biased when the underlying band peak is sharply curved relative to the pixel spacing, and 0.9891, 0.0132 and 0.0004 are peak and lowest figures from the validation set, not population means across all logs [7].
Supplying detail is a different act with a different honesty condition, and our archive states the condition without hedging. Working through 136,771 raster TIF images and 7,781 LAS files, we inpaint across creases, and the rule we held is that inpainting fills a gap from its neighbourhood and does not resurrect information that the fold destroyed. Where a crease had obliterated a long stretch of a curve we marked it as a genuine gap rather than fabricating a confident line through a region where we had nothing [8]. That file's own caveat is that its per-stage increments and raw-scan floor are an illustrative teaching model of which damage costs what, not measured per-stage scores.
The reason that rule exists is not modesty. A fabricated fill is indistinguishable from a real one on every aggregate statistic, and wrong at exactly the point a petrophysicist ties to a formation top.
We do have one case in our record where a factor of resolution was genuinely won, and it is worth being precise about what kind of win it was. On 200+ m of Middle East carbonate borehole image logs we quantified individual vugs at 0.1 m resolution, ranging from 1 to 12 cm squared in area with circularity spanning 0.28 for elongated dissolution-aligned voids to 0.85 for near-circular isotropic ones, and 3 discrete depth intervals showed vugs recovered by automation that manual picking missed [9]. The headline in that file is 2,000 times finer granularity than manual interpretation, and it is measured against zone-level manual picking over tens of metres, not against the instrument. Nothing there went below the pixel. The detail was in the pixels all along and a human workflow could not sustain reading it. That is the honest version of a resolution win, and confusing it with the other kind would collapse this whole argument into the thing it is criticising.
Under all of it sits the floor. At the native digital log resolution one pixel equals about 3 cm, so a plus or minus 3 cm depth uncertainty is baked in before the model makes a single decision, and asking for sub-centimetre agreement on a 3-cm-per-pixel image would be measuring noise [10]. No reduction and no prior lifts that, whatever the upscale factor on the box.
The arithmetic
Here is the arithmetic that decides which acceptance quantity can see the difference, and it needs only two numbers we already measured.
Ship a recovery factor of and each native cell leaves the building as sub-cells. Exactly 1 of those was ever separately measured. The parabolic vertex reads back one fractional offset per spatial axis, which is 3 numbers, and that budget is fixed: subdividing a cell more finely adds no samples to the band, so it adds no read-back capacity.
At that is 60 of 64. Something fills them, because a shipped grid has no empty slots, and the only candidate is a prior.
Now grade a supplied value. It is an independent draw from the prior's marginal for this rock type: right in distribution, uncorrelated with where this rock put this pore. The spread of the truth follows from our own two measured figures without any new assumption, because R-squared is by definition the ratio of residual variance to truth variance.
The squared error of an independent draw against truth is the variance of a difference of two independent draws, which is twice that, 0.0733945, or 183.49 times our measured MSE. Under a Gaussian marginal, which is the one assumption in the chain and is stated on the exhibit, the absolute error is 2 sigma over the square root of pi, which is 0.2161582, or 16.38 times our measured MAE. Mixing the two populations linearly and dividing through by the truth variance then collapses the curve-shape score to a straight line in the supplied share .
Two things fall out of that line. The first holds whatever the constants are: at the score reaches exactly -1, the textbook value for predicting independent draws from the right marginal, worse than quoting the mean. The second is ours, because the crossing is and our own peak R-squared is in it: the line crosses zero at a supplied share of 49.7%, which is 3.978 sub-cells of 8. A lower measured R-squared would move that crossing earlier, not later. The first doubling alone, at a prior weight of zero, already puts 4 of 8 sub-cells in the supplied population. A factor of 2 is past the crossing before anybody touches a dial.
An aggregate over the same population behaves in the opposite direction, and the reason is equally standard. An aggregate is an expectation, the prior's marginal is the right marginal, so the error is sampling noise over the supplied count and falls like 1 over the square root of the population.
That coefficient is not fitted to a curve. It is set by one point: the paper's own operating point, a factor of 4 with the prior carrying what it can.
The instrument
- Mask overlap, measured
- 51.0%
- Aggregate topology, modelled
- 98.76%
- Curve shape, modelled
- -0.8757
- Point value MAE, modelled
- 0.2035
- On the audited slice, 1536 sub-cells
- 24 measured, 72 read back, 1440 supplied
- Supplied share of the slice
- 93.75%
- Aggregate, whole block
- 99.49%
- Mask overlap, whole block
- 51.0%
The exhibit is a volume and not a surface, for a reason. A height field carries one value at each point of a floor plane, which means it can only ever display an aggregate, and the claim being contested is whether any individual recovered element is where the rock put it. So the object is a patch of borehole wall: 144 native instrument cells, 8 around the wall by 6 down the well by 3 into the formation, covering 18 cm of well. One cell is one pixel, and one pixel is about 3 cm, which is ours and measured [10]. The radial axis runs 0 to 30 inches, the high-resolution image log's depth of investigation, with the compact microresistivity tool's 0.90 inches marked at 3.0% of that extent [9].
The recovery factor is the only control that changes how many objects exist. At 1 each native cell is a single box and nothing has been recovered. At 4 it is 64 sub-cells of 0.75 cm each, and the plus or minus 3 cm floor spans 8 of them. The prior weight reassigns sub-cells between two provenances and the population recolours as you drag: aqua is measured, steel is read back, amber is supplied because nothing else could have filled it. The audit plane sweeps down the depth axis and regrades on only the cells it touches, which is the petrophysicist's own gesture, because tying to a formation top is an act performed at one depth. The floor shell draws the measured 3 cm cell as a cage round every native cell, so everything inside one is visibly a claim made below the instrument floor. And gap, not fill replays the archive rule across a fold band: supplied sub-cells there become declared voids you can see straight through.
The block is not the only thing drawn. The framed row is the audited slice, and the same slice is carried down twice, because the four acceptance quantities look at it through different footprints. The point value and the curve shape grade single sub-cells, so they read the framed row in place. The mask is scored on native cells, where down-sampling returns the input, so the first slab is the row after the mask has seen it: 24 native cells, identical at every recovery factor and every prior weight. The aggregate is one number for the whole slice, so the second slab is one body. A test cannot adjudicate a claim finer than its own resolution, and the two slabs are what that looks like.
Every measured anchor is labelled measured, on the stage or in the note beneath it, with its source named. The read-back ceiling, the rate at which the four readouts diverge, and the void network between the measured vugs are our model and are labelled modelled. The micro-CT figures sit on it as an external reference point, reported by academic authors from the JPT summary with no operator named, and the instrument says nothing about micro-CT: every anchor in it is a log image or a scanned raster.
What the exhibit shows
It opens at the paper's own operating point, recovery factor 4 with the prior weight at 0. Drag the factor down to 1 first, because that is the honest state: all four readouts sit on their anchors: mask overlap 51.0%, aggregate 100.00%, curve shape 0.9891, point MAE 0.0132. Nothing has been recovered, so nothing has been invented.
Take the recovery factor back to 4 and the hero tally reads 64 : 1. Three sub-cells per native cell are read back, 60 are supplied, and the supplied share of the audited population is 93.75%. Now watch which readouts notice.
Mask overlap does not move. It reads 51.0% at every recovery factor and at every prior weight, and that is not a modelling shortcut: a mask metric is a native-resolution object, the recovered detail lives entirely inside a native cell, and downsampling the recovered volume returns the input. The mask cannot see what you just did. That is why our own whitepaper records it for training diagnostics and never quotes it as an acceptance number [7].
The aggregate barely moves either, and it moves in the wrong direction. Over the whole block at a factor of 4 our modelled aggregate topological accuracy reads 99.49%, against the 99.48% reported by the paper's academic authors, who name no operator, and taken from the JPT summary rather than from the paper itself [1], for a reconstruction that is almost entirely generated. It reads 98.95% at a factor of 2, which is worse, because a factor of 2 gives the aggregate a smaller population to average over. Subdivide harder and the aggregate looks better. That is the perverse incentive an aggregate acceptance test creates, sitting in plain view.
The other two readouts collapse. Curve shape falls from 0.9891 to -0.8757. Point-located MAE rises from 0.0132 to 0.2035, a factor of 15.41, and MSE from 0.0004 to 0.068832, a factor of 172.08. One object, one visible population, four acceptance quantities, and they do not agree with each other at all.
Now drag the prior weight, with the recovery factor at 2 where the dial has the most room. Supplied sub-cells go from 4.00 of 8 to 7.00 of 8. The aggregate moves 0.338 points, from 98.95% to 98.61%. Mask overlap moves 0.000 points. Curve shape moves 0.7459, from -0.0055 to -0.7514, and point MAE moves 0.0761, a factor of 1.66. The block barely changes to look at, and the two slabs below it do not change at all, while the readouts split apart, which is the sentence the exhibit exists to make and one prose can only assert.
Then sweep the audit plane and the disagreement acquires a location. On one slice at a factor of 4 the aggregate reads 98.76% against 99.49% over the whole block, because the audited population has shrunk by a factor of 6 and the sampling error has grown by 2.449, which is the square root of 6. An aggregate is a number over a population and gets worse the moment you site it. The point-located error does not care: it lands on a named sub-cell at a named depth, which is the only place a formation top can be tied.
Finally, turn on gap, not fill with the plane in the fold band. The block empties there, from 9,216 drawn sub-cells to 7,776. On that slice 96 of 1,536 sub-cells are left standing, which are the measured one and the three read back in each of the 24 native cells. Mask overlap on the slice goes to 0.0%, and over the whole block from 51.0% to 46.1%, because a declared absence scores nothing. Curve shape returns to 0.9891 and point MAE to 0.0132, because a declared absence misleads nobody. That trade, an aggregate metric punishing you for the only honest move available, is the whole reason the rule has to be a policy rather than a preference.
Where this model is weakest
The read-back ceiling of 3 sub-cells per native cell is ours and is the softest number in the chain. It comes from the structure of the estimator, one fractional offset per spatial axis, and a reader who thinks the band supports more should say so and move the argument, not the slider. What survives any value put on it is the direction: the budget is fixed by the band, and subdividing does not enlarge it.
The Gaussian marginal behind the supplied-cell MAE is an assumption, and it is the only one. The supplied-cell MSE is not: the variance of a difference of two independent draws is twice the variance whatever the distribution.
Our measured anchors are peak and lowest figures from a validation set, not population means, and the parabolic estimator carries its own bias on sharply curved band peaks [7]. The fold band is a modelled feature drawn from a file whose own per-stage figures are an illustrative teaching model [8]. And the domains do not match: every anchor in this exhibit is a log image or a scanned raster at centimetre scale, and the paper works on micro-CT at micrometre scale on different rock. The paper's figures are held at arm's length as a reference point for that reason, and a second measured corner of our own on volumetric imagery would be what lets the instrument speak about the paper's own domain instead.
Four questions before you accept recovered resolution
Which of the four routes produced it? Better instrument, read back, supplied, or not yet built. A vendor will not draw that line, because neither side of it has an incentive to.
How many of the shipped values were ever separately measured? Not the factor. The count. At a factor of 4 the answer is 1 in 64, and asking it out loud changes the conversation.
Is your acceptance quantity an aggregate the prior was trained to preserve, or a value at a depth the prior knows nothing about? Where it is an aggregate, a factor of 4 is worth having and worth paying for. Where it is a value at a depth, a factor of 4 bought from a prior is a factor of 4 of confident invention.
What happens to your score when you declare a gap instead of filling it? If declaring the gap makes your headline number worse, your headline number is rewarding fabrication, and the only honest move is the one our archive forced on us: mark the gap anyway.
Key takeaways
- Five releases, none out of window, and four of them say nothing about AI: Equinor and Emerson's 13-year measurement instrumentation frame agreement of 24 August 2026, announced by Emerson and not by Equinor; SLB's ExaCT launch of 24 August, where every AI string on the page is in the site navigation menu; Baker Hughes' 10 August award from the Eni and PETRONAS joint venture for Kutei Northern Hub, which is digital condition monitoring and not AI; and the Aramco and Quantinuum non-binding MOU of 31 August, which is quantum and not machine learning. The AI question here is ours and no operator asked it.
- The only machine learning in the pool is SPE Journal 234678, a Swin-transformer GAN upscaling micro-CT carbonate imagery from 10.72 to 2.68 micrometres per pixel at 99.48% Euler number accuracy. Its authors are academic, it names no operator, and every figure from it is taken from the JPT summary because the OnePetro landing page returns 403.
- On our reading there are four ways to get a number below your measurement floor: buy a better instrument, read back detail the instrument recorded and your reduction discarded, have a model supply detail the instrument never recorded, or wait for a machine that does not exist. Only the middle two are confused with each other, and they fail in opposite directions on different quantities.
- Ship a factor of 4 and 64 values leave the building per native cell. One was ever separately measured and at most 3 more were read back, because a three-point parabolic vertex reads one fractional offset per spatial axis and subdividing adds no samples to the band. The other 60 came from a prior.
- Our two measured figures fix the rest without a new assumption: Var(truth) = 0.0004 / (1 - 0.9891) = 0.0366972, so a supplied value carries 183.49 times our measured MSE, the curve-shape score is 0.9891 minus 1.9891 times the supplied share, it reaches exactly -1 when everything is supplied, and it crosses zero at a supplied share of 49.7%. A factor of 2 is already past that crossing.
- On the same visible population the four acceptance quantities disagree completely. Mask overlap holds at our measured 51.0% and does not move with the recovery factor or the prior weight at all. The modelled aggregate reads 99.49% at a factor of 4, against the 99.48% the paper's academic authors report through the JPT summary, and it reads a worse 98.95% at a factor of 2 because there is less to average. Curve shape falls to -0.8757 and point MAE rises to 0.2035, a factor of 15.41 on our measured 0.0132.
- Siting the aggregate makes it worse: on one audited slice it reads 98.76% against 99.49% over the block, the sampling error having grown by 2.449, the square root of 6. Declaring the fold band void instead of filling it takes mask overlap on that slice to 0.0% and over the block from 51.0% to 46.1%, while returning curve shape to 0.9891 and point MAE to 0.0132. If the honest move costs you your headline number, the headline number is the problem.
References
[1] Journal of Petroleum Technology. Super-Resolution of Carbonate Rock Images Beyond Instrument Limitations. Summary of SPE Journal paper SPE 234678, 9 September 2026. Authors are academic (Eastern Institute of Technology, Imperial College London, University of New South Wales) and no operator is named. Every micro-CT figure quoted in this piece is taken from this summary. https://jpt.spe.org/super-resolution-carbonate-rock-image-beyond-instrument-limitations
[2] Society of Petroleum Engineers. SPE Journal paper 234678, OnePetro article landing page. Cited to record that the page returns HTTP 403 and that the figures above therefore come from the JPT summary and not from the paper itself. https://doi.org/10.2118/234678-PA
[3] Emerson, via PR Newswire. Emerson's Advanced Measurement Instrumentation Selected by Equinor To Optimize Operations, Accelerate Development. 24 August 2026, dateline Stavanger. Partner release: a vendor speaking about an operator. Equinor is named and not quoted, and Equinor's own newsroom contains zero occurrences of "Emerson". The release body contains no mention of AI, machine learning, analytics or data. https://www.prnewswire.com/news-releases/emersons-advanced-measurement-instrumentation-selected-by-equinor-to-optimize-operations-accelerate-development-302857353.html
[4] SLB. SLB Launches ExaCT Electrical Downhole Coiled Tubing Control System. 24 August 2026, dateline Houston, first-party newsroom. No operator is named in the release body; the performance figures are vendor-reported single-well trial figures with the operator unnamed. Every "Artificial Intelligence", "agentic" and "Autonomous" string on the fetched page is in the site navigation menu, not in the release. https://www.slb.com/newsroom/press-release/2026/slb-launches-exact-electrical-downhole-ct-control-system
[5] Baker Hughes. Baker Hughes To Supply Subsea Systems for Kutei Northern Hub Development in Indonesia. 10 August 2026, dateline Houston and London. The vendor's own release, first-party for Baker Hughes; the operator has not spoken here. Contract award with future-tense scope; the words artificial intelligence, AI, machine learning and analytics do not appear on the page. https://investors.bakerhughes.com/news/press-releases/news-details/2026/Baker-Hughes-to-Supply-Subsea-Systems-for-Kutei-Northern-Hub-Development-in-Indonesia/default.aspx
[6] Quantinuum. Quantinuum Signs Non-Binding MOU With Aramco To Explore Synergies Leveraging Industrial Quantum Computing Research, Applications and Expertise. Signing dateline Riyadh, 31 August 2026; page published 3 September 2026. The vendor's own account, not Aramco's, whose newsroom carries no Quantinuum item. No hardware, no deployment, no dollar figure and no timeline are named. https://www.quantinuum.com/press-releases/quantinuum-signs-non-binding-mou-with-aramco-to-explore-synergies-leveraging-industrial-quantum-computing-research-applications-and-expertise
[7] EarthScan. Sub-Pixel Centrelines and Depth Registration: A Validation Framework for Digitised Curves. Source file content/whitepapers/sub-pixel-centreline-depth-registration-validation-framework.mdx. Peak R-squared 0.9891, lowest MAE 0.0132, lowest MSE 0.0004 at 300 interpolated depth points, against a peak mask IoU of 0.51 on the same checkpoints; those are peak and lowest figures from the validation set, not population means. https://www.earthscan.io/whitepapers/sub-pixel-centreline-depth-registration-validation-framework
[8] EarthScan. The Coffee Ring and the Crease: Recovering Folded, Stained, Skewed Field Scans. Source file content/case-studies/deskew-and-fold-stain-recovery-on-real-field-scans.mdx. Archive of 136,771 raster TIF images and 7,781 LAS files; clean-image ceiling IoU 0.51 with recall 0.97 and F1 0.55; the file's per-stage increments and raw-scan floor are an illustrative teaching model, not measured per-stage scores. https://www.earthscan.io/case-studies/deskew-and-fold-stain-recovery-on-real-field-scans
[9] EarthScan. From Pixels to Pores: Automated Vug Detection in Carbonate Reservoirs. Source file content/case-studies/from-pixels-to-pores-automated-vug-detection-carbonate-reservoirs.mdx. Vugs quantified at 0.1 m resolution across 200+ m of Middle East carbonate borehole image logs, 1 to 12 cm squared in area, circularity 0.28 to 0.85, 3 intervals recovered that manual picking missed; the 2,000 times figure is measured against zone-level manual interpretation, not against the instrument. https://www.earthscan.io/case-studies/from-pixels-to-pores-automated-vug-detection-carbonate-reservoirs
[10] EarthScan. Proving It Generalises: A Blind Zone the Model Had Never Seen. Source file content/case-studies/blind-zone-validation-repeatability-unseen-well-milestone.mdx. At the native digital log resolution one pixel equals about 3 cm, so a plus or minus 3 cm depth uncertainty is baked in before the model makes a single decision, and that pixel floor caps how tight any depth tolerance can ever be. https://www.earthscan.io/case-studies/blind-zone-validation-repeatability-unseen-well-milestone