On our synthetic storage unit the isothermal pressure envelope sustains 776 t/d of CO2, 0.283 Mt/yr, for five years. The CO2 does not reach the sandface at reservoir temperature. Leaving the wellhead at 20 C, it arrives 40.8 C colder than the rock at that rate, the cooled rock carries 2.7 MPa less minimum stress, and the allowable pressure falls from 27.48 to 25.03 MPa. A slower rate arrives warmer, so we close the loop: it settles at 460 t/d, 0.168 Mt/yr, with the CO2 still 36 C below the rock. Insulating the tubing cuts the rate further, to 0.132. Warming the wellhead CO2 to 45 C lifts it to 0.206 for a 0.45 MW heater.

On a synthetic storage unit, a pressure envelope written at reservoir temperature sustains 776 t/d of CO2, or 0.283 Mt/yr, for five years with the high-case pressure under the limit. Count the temperature the CO2 actually reaches the rock at, and the same well sustains 460 t/d, or 0.168 Mt/yr: 41% less. At that rate the CO2 leaves the wellhead at 20 C and reaches 1,800 m at 34.1 C, 35.9 C colder than the formation. The cooled rock holds less minimum horizontal stress, and the stress sets the limit.

Our brine-offtake piece priced a pressure-management well on this unit and held the reservoir at constant temperature throughout. This piece takes the temperature back. Every rate here comes from the same synthetic unit and the same injection guardian, now with a wellbore mechanics run attached. None of it is a field result.

The CO2 is not at reservoir temperature

Cold arrival is a measured fact at real sites. At In Salah in Algeria, CO2 entered the wellhead at 35 C and reached the storage formation at 50 C, 45 C colder than the rock [1]. At Cranfield in Mississippi, the bottom-hole temperature rose by 16 C when the mass rate was cut by a factor of 4, as the review by Vilarrasa and Rutqvist reports it: the faster the CO2 goes down, the less the formation warms it [2]. Shell's guidelines for the Peterhead wells expected CO2 at the tree at 2.3 to 10.1 C, a reservoir at 83 C, and bottom-hole temperatures in the order of 20 to 25 C after a long period of injection [3].

Cooling contracts the rock and takes stress off it. If the allowable injection pressure is a fraction of the minimum horizontal stress, the allowable pressure falls with it. In Salah's coupled model puts the thermal reduction in the minimum effective stress at the base of the caprock at 3 MPa after 30 years of injecting CO2 45 C colder than the formation [1].

Between the gauge and the compressor

The injection guardian forecasts bottom-hole pressure at the gauge. The mechanics run adds what sits between that pressure and the plant: the wellhead pressure the compressor must deliver, the temperature the CO2 reaches the sandface at, and the envelope corrected for the cooling. It marches pressure and temperature down the tubing and then applies the thermal stress:

Pressure and temperature down the tubing, and the stress the cooling removes
dPdz=ρ(P,T) g−fD ρv22,dTdz=Tearth(z)−TA,A=m˙ cp2πrU,Δσh=E α (Tres−Tbh)1−ν×η\frac{dP}{dz} = \rho(P,T)\,g - \frac{f}{D}\,\frac{\rho v^2}{2}, \qquad \frac{dT}{dz} = \frac{T_{earth}(z) - T}{A}, \quad A = \frac{\dot m\,c_p}{2\pi r U}, \qquad \Delta\sigma_h = \frac{E\,\alpha\,(T_{res} - T_{bh})}{1-\nu} \times \eta

The first term is the weight of the column less friction. The second is Ramey's steady heat balance, in which the CO2 relaxes towards the geotherm over a length A that grows with the mass rate and shrinks with the overall heat-transfer coefficient U [4]. The third is the thermo-elastic stress reduction, scaled by an efficiency factor for a cooled zone of finite size.

Density, heat capacity and viscosity come from the Span and Wagner equation of state [5] through CoolProp, which is MIT licensed. Compression follows McCollum and Ogden: five stages from the inlet to the 7.38 MPa critical pressure, an isentropic efficiency of 0.75, intercooling to 40 C, and a pump at 0.75 efficiency above the critical pressure [6].

The rock values are In Salah's reservoir inputs, E = 10 GPa and a thermal expansion coefficient of 1e-5 per C [1]. With a Poisson ratio of 0.25 and an efficiency of one half, the run takes 0.0667 MPa of minimum stress off the reservoir for every degree of cooling, and a quarter of that off the caprock. U = 15 W/m2K on the tubing radius is an engineering assumption, and the one that matters most here, so the exhibit below lets you change it.

Our check script holds 32 assertions. A static column adds rho g h to within 1%. The marched column lands on the target pressure to 2 kPa. A single low-pressure compressor stage matches the ideal-gas isentropic work to within 3%, and pump work equals the pressure rise over density over efficiency. A mechanics run that is a child of a guardian run reads its case from the parent and replays to the same hash.

The as-is run, at 776 t/d

The guardian's as-is strategy on this unit keeps the existing brine producer running and drills nothing. It sustains 776 t/d for five years, with the P90 pressure just touching the 27.48 MPa isothermal limit. The mechanics run at that rate gives:

QuantityValue
Wellhead pressure for 27.48 MPa at 1,800 m11.48 MPa, dense-phase liquid at 20 C
Mean column density; friction919 kg/m3; 0.22 MPa
Bottom-hole temperature29.2 C, 40.8 C below the formation
Compression from 0.15 to 11.48 MPafive stages and a pump, 94.5 kWh/t, 3.06 MW
Stress reduction from the cooling2.72 MPa in the reservoir, 0.69 MPa in the caprock
Allowable pressure with the cooling25.03 MPa, reservoir stress binding, against 27.48 isothermal

At 776 t/d the forecast sits 2.45 MPa above the cooled limit. The wellhead pressure checks by hand: 27.48 MPa less 919 kg/m3 times g times 1,800 m, which is 16.23 MPa, plus 0.22 MPa of friction, is 11.47 MPa.

Closing the loop

The guardian rerun with 25.03 MPa as the limit sustains about 416 t/d. At that slower rate the CO2 spends longer passing warm rock and arrives at 35.2 C, and the limit rises to 25.40 MPa. Rerun again and the rate rises to 469 t/d. The passes go 776, 416, 469, 458, 460 t/d and settle at 460 t/d, 0.168 Mt/yr, with the CO2 arriving at 34.1 C under a limit of 25.33 MPa. The first pass undershoots: 0.152 Mt/yr is what you get if you stop after correcting the limit once.

The guardian's pressure model is linear in the rates, so its five-year P90 pressure is a straight line in the injection rate. Its two runs, 776 t/d at 27.48 MPa and 417 t/d at 25.04 MPa, fix that line, and the loop's later passes read off it rather than rerunning the match. This is a hand-run loop on one line, not a coupled thermal and flow solve.

COLD CO2 AND THE SUSTAINABLE RATE · SYNTHETIC UNIT, 1,800 M0.283MT/YR AT RESERVOIR TEMPERATURE0.168MT/YR WITH THE COOLINGAt 20 C at the wellhead and U = 15 W/m2K the loop settles at 460 t/d: the CO2 arrives at 34.1 C, 35.9 C below the rock.Allowable 25.33 MPa against 27.48 isothermal. 0.168 Mt/yr against 0.283: 41% less.06001,2001,80010305070CO2 temperature, C; depth, mDOWN THE TUBING31 Cgeotherm35.9 C below the rock460 t/d776 t/d20 C in222324252627283006009001,2001,500constant injection rate, t/dBOTTOM-HOLE MPA: THE LIMIT, AND WHAT THE RATE NEEDSlimit at reservoir temperature, 27.48limit with the coolingfive-year P90 pressure the rate needs460 t/d against 7760.100.150.200.250.301020304050CO2 at the wellhead, CSETTLED MT/YR, BY TUBING Uisothermal 0.283U 2, insulatedU 5U 15U 400.168At the settled rate: compression 1.81 MW. Wellhead 11.46 MPa, dense-phase liquid.Run the loop: 776 t/d under the cooled limit sustains 416, which arrives warmer, and the passes settle at 460.Grid: 13 rates x 9 wellhead temperatures x 4 tubing U from the EarthScan mechanics bench (CoolProp, Ramey, McCollum and Ogden), synthetic.Guardian line through 776 t/d at 27.48 MPa and 417 t/d at 25.04. Heater from NIST enthalpies.
tubing U, W/m2K:

At 20 C at the wellhead and U = 15 W/m2K the loop settles at 460 t/d: the CO2 arrives at 34.1 C, 35.9 C below the rock. Allowable 25.33 MPa against 27.48 isothermal. 0.168 Mt/yr against 0.283: 41% less. At the settled rate: compression 1.81 MW. Wellhead 11.46 MPa, dense-phase liquid.

The injection guardian's synthetic storage unit with the mechanics run attached: 1,800 m of tubing, a 70 C formation, and a 27.48 MPa envelope written at reservoir temperature. Left: CO2 temperature down the tubing at the settled rate (aqua) and at the isothermal 776 t/d (steel), against the geotherm; the gap at the sandface is what the rock is cooled by. Middle: the guardian's five-year P90 pressure against injection rate (steel) meets the isothermal limit at 776 t/d, 0.283 Mt/yr, and the limit with the cooling (aqua) at 460 t/d, 0.168 Mt/yr, where the CO2 arrives at 34.1 C. Run the loop to see the hand-run passes. Right: the settled rate for each wellhead temperature and tubing coefficient; insulated tubing is the lowest curve whenever the CO2 starts colder than the rock. Bench grid values are synthetic (CoolProp Span and Wagner, Ramey heat balance, McCollum and Ogden compression); the heater duty uses NIST enthalpies; the profile shape is a Ramey curve fitted to the grid, with its end on the grid's bottom-hole temperature.

The exhibit opens on the settled state. The left panel draws the CO2 down the tubing against the geotherm at 460 t/d and at 776 t/d. The middle panel is the loop itself: the guardian's forecast line crosses the isothermal limit at 776 t/d and the cooled limit at 460, and "run the loop" draws the passes as a staircase between them. The right panel repeats that crossing for every wellhead temperature from 10 to 50 C and for each tubing coefficient. Drag the wellhead temperature down and the settled rate falls: 0.157 Mt/yr at 10 C on bare tubing. The colder the CO2 starts, the further the four curves spread apart, and the lowest is always the insulated one.

Insulating the tubing makes it worse

Settled caseRate, t/dMt/yrBottom-hole CAllowable, MPaCompression, MWHeater, MW
As is: 20 C at the wellhead, U = 15 W/m2K4600.16834.125.331.810
Insulated tubing, U = 2 W/m2K3610.13222.924.661.410
Wellhead CO2 warmed to 45 C, U = 15 W/m2K5630.20645.826.032.290.45
One more 800 m3/d brine producer, 20 C, U = 15 W/m2K9450.34527.724.943.720

Insulating the tubing keeps the CO2 cold all the way down. The formation was the only heater in the system, and insulation takes it out, so the rate falls from 0.168 to 0.132 Mt/yr. A tubing that exchanges heat freely, U = 40 W/m2K, settles at 0.202 Mt/yr. Since U is our assumption, the honest reading is that the sustainable rate on this unit lies somewhere between 0.13 and 0.20 Mt/yr for CO2 leaving the wellhead at 20 C, until a distributed temperature survey or a bottom-hole gauge pins the arrival temperature down.

Warming the wellhead CO2 to 45 C buys 0.038 Mt/yr. It costs a heater. Warming the settled 563 t/d from 20 to 45 C at the 13.2 MPa wellhead pressure takes 0.45 MW of heat by NIST enthalpies [7], about 19 kWh of heat per tonne beside 97.4 kWh/t of compression. Counting only the compression understates it badly. At a fixed 776 t/d, warming to 45 C adds 0.98 MPa of envelope; the warmer, lighter column needs a higher wellhead pressure, which costs 3.1 kWh/t, or 0.10 MW, more compression, and the heat itself is 0.61 MW, six times as much. Whether that heat is cheap depends on whether it comes from compressor intercooling, which the bench does not credit.

A brine producer is worth less once the cooling is counted

The brine-offtake piece found that one more 800 m3/d producer lifts the isothermal rate from 0.283 to 0.481 Mt/yr. A producer shifts the guardian's pressure line down without changing its slope, so the same loop applies. With the cooling counted, the unit with the producer settles at 945 t/d, 0.345 Mt/yr. The producer is worth 0.177 Mt/yr against 0.198 isothermal, because the faster injection it allows arrives colder: 27.7 C at the sandface against 34.1 C without it.

The choke matters at start-up and low rate

In dense phase the Joule-Thomson effect is small. Dropping CO2 at 20 C from 12 to 10.5 MPa through a choke cools it by 0.8 C on the NIST tables. Near saturation it is a different matter. CO2 at 6 MPa and 20 C sits just above its 5.73 MPa saturation pressure; let it down to 3 MPa and it flashes to a two-phase mixture at minus 5.6 C, about a quarter of it vapour by mass [7].

Peterhead's well operation guidelines are written around this. They state that the wellhead temperature is set mostly by Joule-Thomson cooling over the wellhead choke. They set a minimum tubing head pressure of 50 bara for steady injection, which keeps the arriving CO2 above its saturation pressure, and an absolute minimum of about 30 bara at start-up and low rate, where the saturation temperature is minus 5.5 C. Part of the wellhead is rated to minus 18 C, but the subsurface safety valve could only be operated down to minus 7 C, so the guidelines are designed to keep the valve wall above that temperature [3]. Our module flags a wellhead within 5% of saturation and two-phase conditions in the tubing. It does not model them, and every case in the tables above stays in dense phase.

Key takeaways

  1. On the synthetic unit the isothermal envelope sustains 776 t/d, 0.283 Mt/yr, for five years at the P90 pressure.
  2. At 776 t/d CO2 leaving the wellhead at 20 C reaches 1,800 m at 29.2 C, 40.8 C below the rock; the reservoir loses 2.72 MPa of minimum stress and the allowable pressure falls from 27.48 to 25.03 MPa.
  3. The loop of rate, arrival temperature and limit passes 776, 416, 469, 458 and settles at 460 t/d, 0.168 Mt/yr, with the CO2 still 35.9 C below the rock.
  4. Insulated tubing (U = 2 W/m2K) settles at 0.132 Mt/yr and freely conducting tubing (U = 40) at 0.202, so the assumed U spans more rate than any other input here.
  5. Warming the wellhead CO2 to 45 C settles at 0.206 Mt/yr for a 0.45 MW heater; at 776 t/d the heat is six times the extra compression.
  6. One more 800 m3/d brine producer is worth 0.177 Mt/yr with the cooling counted, against 0.198 isothermal, because faster CO2 arrives colder.
  7. Joule-Thomson cooling is under a degree in dense phase and decisive near saturation; at Peterhead the governing limit was minus 7 C at the subsurface safety valve.

Limitations

Every rate, pressure and temperature in the tables is synthetic. The unit, the guardian's forecasts and the mechanics grid come from the same bench as the brine-offtake piece, and nothing here has been matched to a measured wellbore temperature.

The heat balance is steady. A well that has just started, or one injecting at a varying rate, has not reached the profile drawn here, and the near-well rock cools progressively over months to years, so the stress reduction applies to a zone that grows with time.

U = 15 W/m2K is assumed, and the settled rate moves from 0.132 to 0.202 Mt/yr across the four values in the grid. A temperature log or a bottom-hole gauge would replace it.

The stress reduction is a scaled thermo-elastic bound. The efficiency factor of one half and the Poisson ratio of 0.25 are ours. With In Salah's own reservoir Poisson ratio of 0.2, E alpha delta T over (1 minus nu) at 45 C is 5.6 MPa, and In Salah's coupled model gives 3 MPa [1], which is consistent with a factor near one half. But In Salah's 3 MPa is at the base of the caprock, where this module puts only a quarter of the reservoir figure, 0.69 MPa at 776 t/d. The caprock fraction is optimistic against that comparison. It does not bind here, because the reservoir stress does, but on a site where the caprock sets the limit it would.

The loop reads later passes off a straight line through two guardian runs. The guardian's model is linear in the rates, so the line is close, but the settled 460 t/d has not been confirmed by a third guardian run at 25.33 MPa.

Two-phase flow, start-up transients and hydrates are flagged and not modelled.

References

  1. V. Vilarrasa, J. Rutqvist and A. P. Rinaldi. Thermal and capillary effects on the caprock mechanical stability at In Salah, Algeria. Greenhouse Gases: Science and Technology, 5(4):449-461, 2015. CO2 injected at 35 C at the wellhead reaching the formation at 50 C, 45 C colder than the 95 C formation; reservoir E = 10 GPa, Poisson ratio 0.2, thermal expansion 1e-5 per C; a 3 MPa thermal reduction in the minimum effective stress at the base of the caprock after 30 years: osti.gov/biblio/1407269.
  2. V. Vilarrasa and J. Rutqvist. Thermal effects on geologic carbon storage. Earth-Science Reviews, 165:245-256, 2017. At Cranfield the bottom-hole CO2 temperature rose by 16 C when the mass rate was cut by a factor of 4 (reporting Luo et al., 2013): digital.csic.es/handle/10261/156489.
  3. Shell U.K. Limited. Peterhead CCS Project, Well Operation Guidelines, PCCS-05-PT-ZR-7180-00003, revision K02, 12 May 2015, published by the UK government. CO2 arrival temperature 2.3 to 10.1 C; reservoir 83 C; bottom-hole temperatures of 20 to 25 C after long injection; Joule-Thomson cooling over the choke; 50 bara steady and 30 bara absolute minimum tubing head pressure; temperature limits of minus 18 C for part of the wellhead and minus 7 C at the subsurface safety valve: assets.publishing.service.gov.uk.
  4. H. J. Ramey. Wellbore heat transmission. Journal of Petroleum Technology, 14(4):427-435, 1962: doi.org/10.2118/96-PA.
  5. R. Span and W. Wagner. A new equation of state for carbon dioxide covering the fluid region from the triple-point temperature to 1100 K at pressures up to 800 MPa. Journal of Physical and Chemical Reference Data, 25(6):1509-1596, 1996: doi.org/10.1063/1.555991. Implemented in CoolProp, MIT licence: coolprop.org.
  6. D. L. McCollum and J. M. Ogden. Techno-economic models for carbon dioxide compression, transport, and storage. UC Davis Institute of Transportation Studies, UCD-ITS-RR-06-14, 2006. Five stages to a 7.38 MPa cut-off, isentropic efficiency 0.75, inlet at 40 C, pump efficiency 0.75: itspubs.ucdavis.edu.
  7. NIST Chemistry WebBook, thermophysical properties of carbon dioxide (Span and Wagner), isobars from 3 to 15 MPa and saturation properties, retrieved 19 October 2026: webbook.nist.gov/chemistry/fluid.
  8. EarthScan injection guardian and injection-mechanics bench, synthetic data throughout: available on request.
Tannistha Maiti
Tannistha Maiti

Head of Engineering

More from EarthScan

Related research

All insights →
Lifting 800 m3/d of Brine Makes Room for 0.2 Mt/yr More CO2 in a Closed Aquifer
Insight

Lifting 800 m3/d of Brine Makes Room for 0.2 Mt/yr More CO2 in a Closed Aquifer

Rate Is Not Capacity: What a Pressure Ceiling Does to a Storage Ranking
Insight

Rate Is Not Capacity: What a Pressure Ceiling Does to a Storage Ranking

Agentic CCS: Months of Site Screening in Minutes
Research

Agentic CCS: Months of Site Screening in Minutes

Stay ahead

EarthScan insights, in your inbox.

Field-tested research on subsurface and energy-transition AI. About twice a month. No noise.

We use your email only for this newsletter. Unsubscribe anytime Privacy.